Rohde & Schwarz RTB2K-302M Oscilloscopio MSO 300MHz 2 Canali

Rohde & Schwarz RTB2K-302M Oscilloscopio MSO 300MHz 2 Canali
Rohde & Schwarz RTB2K-302M Oscilloscopio MSO 300MHz 2 Canali
Produttore: Rohde & Schwarz
Codice Prodotto: RTB2K-302M
SKU: 1333.1005P33
Disponibilità: In magazzino
Prezzo IVA esclusa: 3.670,00€

Opzioni disponibili


R&S RTB-PK1 50% OFF:

Qtà:  
   - O -   
Il Rohde & Schwarz RTB2K-302M Oscilloscopio MSO 300MHz 2 Canali. Si contraddistingue per convertitore analogico digitale a 10bit (ADC), il display touch screen da 10.1" e la profondità di memoria da 10Mpts.
 
La confezione del R&S RTB2K-302M contiene:
- oscilloscopio digitale 70MHz 2 canali
- 2 sonde modello R&S RT-ZP03 (300 MHz, 10 MHz, 10:1/1:1, 10 MΩ/1 MΩ, 400 V, 12 pF/82 pF)
- cavo di alimentazione
- R&S®RTB-B1 Mixed Signal Option
- 2 sonde logiche modello R&S RT-ZL03
- R&S®RTB-B223 300MHz bandwidth upgrade
 
Key facts:
- Bandwidth: 70/100/200/300 MHz
- Sample rate: up to 2.5 Gsample/s
- Memory depth: up to 20 Msample
- ADC resolution: 10 bit
- Display: 10.1" capacitive touchscreen
 
General description:
Power of ten (10-bit ADC, 10 Msample memory and 10.1" touchscreen) combined with smart operating concepts make the R&S®RTB2000 digital oscilloscope the perfect tool for 
university laboratories, for troubleshooting embedded designs during development and for production and service departments.
 
The largest display (10.1") with the highest resolution of 1280 × 800 pixel in its class, a capacitive touchscreen to quickly navigate in pop-up menus and a touch function to easily adjust scaling, to zoom in or to move a waveform – works just like your smartphone.
 
The 10-bit A/D converter yields up to a four-fold improvement compared to conventional 8-bit A/D converters. You get sharper waveforms with more signal details.
10 Msample memory depth is available on each channel if all channels are active. When interleaved, 20 Msample are available. That is 10 times more than comparable oscilloscopes offer. This captures longer signal sequences for more analysis results.
 
The R&S®RTB2000 gives users more than just an oscillo- scope. It also includes a logic analyzer, protocol analyzer, waveform and pattern generator and digital voltmeter. Dedicated operating modes for frequency analysis, mask tests and long data acquisitions are also integrated. De- bugging all kinds of electronic systems is easy and efficient – and satisfies the all-important rule of investment protection at a very attractive price.
 
Key features:
 
Oscilloscope
With a sampling rate of up to 2.5 Gsample/s and a memory depth of up to 20 Msample, the R&S®RTB2000 oscilloscope excels in its class. A waveform update rate of more than 50 000 waveforms/s ensures a responsive instrument that reliably catches signal faults. Included standard tools provide quick results, e.g. QuickMeas, mask tests, FFT, math, cursors and automatic measurements, including statistics.

 
Logic analyzer
The R&S®RTB-B1 option turns every R&S®RTB2000 into an intuitive-to-use MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and time- correlated to each other. For example, the delay between input and output of an A/D converter can conveniently be determined using the cursor measurements.

 
Protocol analyzer
Protocols such as I2C, SPI and CAN/LIN frequently transfer control messages between integrated circuits. The R&S®RTB2000 has versatile options for protocol-specific triggering and decoding of serial interfaces. Selective acquisition and analysis of relevant events and data is possible. With the hardware-based implementation, smooth operation and a high update rate is ensured even for long acquisitions. This is advantageous, for example, to capture multiple packetized serial bus signals.

 
Waveform and pattern generator
The integrated R&S®RTB-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Before playing signals back, the user can preview them to quickly check signal correctness. Predefined patterns for e.g. I2C, SPI, UART and CAN/LIN can be used.
 
 
Digital voltmeter
The R&S®RTB2000 features a three-digit voltmeter (DVM) and six- digit frequency counter on each channel for simultaneous measurements. Measurement functions include DC, AC+DCRMS and ACRMS – included in scope of delivery.

 
Frequency analysis mode
Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S®RTB2000 is activated with the push on a button and by just entering center frequency and span. Due to the high-performance FFT functionality of the R&S®RTB2000 oscilloscopes, signals can be analyzed with up to 128k point. Other practical tools include cursor measurements and autoset in frequency domain.


 
Mask test mode
Mask tests quickly reveal whether a specific signal lies within de- fined tolerance limits. By using statistical pass/fail evaluation, they assess quality and stability of a DUT. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse out- put at the AUX-OUT connector on the R&S®RTB2000. This pulse output can be used to trigger actions in the measurement setup.

 
History and segmented memory mode
The R&S®RTB-K15 history function option increases the memory from 10 Msample to 160 Msample. Users scroll through past acquisitions and analyze the data using all of the oscilloscope tools, e.g. protocol decode and logic channels. Serial protocol and pulse sequences are recorded practically without interruptions.

 

MODEL 2 CHANNELS BANDWIDTH MSO
RTB2002 70MHz OPT
RTB2K-72M 70MHz YES
RTB2K-102 100MHz OPT
RTB2K-102M 100MHz YES
RTB2K-202 200MHz OPT
RTB2K-202M 200MHz YES
RTB2K-302 300MHz OPT
RTB2K-302M 300MHz YES
RTB2K-COM2 ALL INCLUSIVE 300MHz YES
     
MODELS 4 CHANNELS BANDWIDTH MSO
RTB2004 70MHz OPT
RTB2K-74M 70MHz YES
RTB2K-104 100MHz OPT
RTB2K-104M 100MHz YES
RTB2K-204 200MHz OPT
RTB2K-204M 200MHz YES
RTB2K-304 300MHz OPT
RTB2K-304M 300MHz YES
RTB2K-COM4 ALL INCLUSIVE 300MHz YES

 