PicoScope 4262 PC Oscilloscope 2 channels, 16-bit, 5 MHz with probes

PicoScope 4262 PC Oscilloscope 2 channels, 16-bit, 5 MHz with probes
Produttore: Pico Technology
Codice Prodotto: PP799
Disponibilità: In magazzino
Prezzo IVA esclusa: 1.045,00€
Qtà:  
   - O -   

PicoScope 4262 PC Oscilloscope 2 channels, 16-bit, 10 MHz with probes

With 16–bit resolution, low noise and low distortion, the PicoScope 4262 has the precision and performance you need.

Main Specs:
Two channels
16–bit  resolution
10 MS/s  sampling
5 MHz  bandwidth
16 MS  buffer memory
Low–distortion signal generator
Arbitrary waveform generator
USB powered

What do I get?
PicoScope 4262 VHRO
2 x oscilloscope probes (x1/x10)
Protective case for scope probes
USB cable
User manuals
PicoScope oscilloscope software
Free software updates
5–year warranty

Selection table:

Product Channels Bandwidth Sampling Rate Buffer Memory Resolution (Enhanced)
4224 2 20 MHz 80 MS/s 32 MS 12  (16 bits)
4224 Kit 2 20 MHz 80 MS/s 32 MS 12  (16 bits)
4224-IEPE 2 20 MHz 80 MS/s 32 MS 12  (16 bits)
4424 4 20 MHz 80 MS/s 32 MS 12  (16 bits)
4424 Kit 4 20 MHz 80 MS/s 32 MS 12  (16 bits)
4262 2 5 MHz 10 MS/s 16 MS 16  (20 bits)
4824 8 20 MHz 80 MS/s 256 MS 12  (16 bits)

 

PicoScope 4262 VHRO Specifications
 

Oscilloscope — Vertical
Bandwidth
±20 mV range
±10 mV range
5 MHz
4 MHz
3 MHz
Bandwidth limiter 200 kHz, switchable
Rise time (calculated)
±20 mV range
±10 mV range
70 ns
88 ns
117 ns
Input Channels 2
Vertical resolution 16 bits
Enhanced vertical resolution 20 bits
DC accuracy (% of full scale)
±50 mV range
±20 mV range
±10 mV range
±0.25%
±0.5%
±1%
±2%
Input sensitivity 2 mV/div to 4 V/div (10 vertical divisions)
Input characteristics 1 MΩ ±2% in parallel with 15 pF ±2 pF
Input type Single–ended, BNC connector
Input coupling Software selectable AC/DC
Input ranges (full scale) ±10 mV to ±20 V in 11 ranges
Overvoltage protection ±50 V (DC+AC peak)

 

Oscilloscope — Horizontal
Maximum sampling rate (single shot) 10 MS/s
Maximum sampling rate
(continuous streaming mode)
Using PicoScope
Using the SDK


10 MS/s
10 MS/s one channel (PC dependent)
6.7 MS/s two channels (PC dependent)
Buffer memory 16 MS
Waveform buffer
Using PicoScope
Using the SDK

Up to 10,000 waveforms
Up to 32,768 waveforms
Timebase ranges 1 µs/div to 5000 s/div
Timebase accuracy ±50 ppm
Sample jitter < 10 ps RMS

 

Dynamic Performance (typical)
Crosstalk > 50,000:1
Total harmonic distortion -95 dB typical @ 10 kHz, -1 dBfs input
SFDR 102 dB typical @ 10 kHz, -1 dBfs input
Pulse response < 1% overshoot on all ranges
Bandwidth flatness ±0.2 dB (DC to full bandwidth)
Noise 8.5 µV RMS (on most sensitive range)

 

Triggers (Channels A and B)
Source Any input channel
Trigger modes None, auto, repeat, single, rapid (segmented memory)
Basic trigger types Rising, falling
Advanced triggers Edge: rising, falling or dual edge with adjustable hysteresis
Window: signal enters or exits a user–defined voltage range
Pulse width: a negative or positive pulse is wider or narrower than a set width, or inside/outside a range of widths
Window pulse width: signal is inside or outside a voltage range for a set time
Dropout: signal does not cross a voltage threshold for at least a set time
Window dropout: signal does not enter or exit a voltage range for at least a set time
Interval: time between two edges is greater or less than a set time, or inside/outside a time range
Logic: arbitrary logic state of Channels A, B and EXT matches a user–defined pattern
Runt pulse: signal crosses one voltage threshold and returns without crossing the other
Trigger sensitivity Digital triggering provides 1 LSB accuracy up to full bandwidth of scope
Maximum pre–trigger capture Up to 100% of capture size
Maximum post–trigger delay Up to 4 billion samples
Trigger re–arm time < 10 µs on fastest timebase

 

External Trigger
Trigger types Edge, pulse width, dropout, interval, logic, delayed
Input characteristics 1 MΩ ±2% in parallel with 15 pF ±2 pF
Input type Rear panel BNC connector
Threshold range ±5 V and ±500 mV, DC coupled
Trigger sensitivity 25 mV p–p at 1 MHz, typical
DC accuracy ±1%
Bandwidth 5 MHz
Overvoltage protection ±50 V

 

Spectrum Analyser
Frequency range DC to 5 MHz
Windowing functions Rectangular, Gaussian, triangular, Blackman, Blackman–Harris, Hamming, Hann, flat–top
Display modes Magnitude, peak hold, average
Number of FFT points Selectable from 128 to 1 million in powers of 2

 

Signal Generator
Standard output signals Sine, square, triangle, DC voltage, ramp, sinc, Gaussian, half–sine, white noise, PRBS
Standard signal frequency DC to 20 kHz
Output frequency accuracy ±50 ppm
Output frequency resolution < 0.01 Hz
Output voltage range ±1 V (into high–impedance load)
Offset voltage adjustment 100 µV steps (within overall ±1 V range)
DC accuracy ±0.5% of full scale
Amplitude flatness < 0.1 dB to 20 kHz, typical
SFDR 102 dB typical @ 10 kHz, -1 dBfs input
Connector type Front panel BNC
Output characteristics 600 Ω
Overvoltage protection ±10 V
Sweep modes Up, down, dual with selectable frequency and sweep time

 

Arbitrary Waveform Generator
Update rate 192 kS/s
Buffer size 4,096 samples
Resolution 16 bits
Bandwidth 20 kHz
Rise time (10% to 90%) 11 µs, typical

 

PC Requirements
Minimum Processor: 1 GHz.
Memory: 512 MB.
Free disk space: 32–bit: 600 MB, 64–bit: 1.5 GB.
Operating system: 32– or 64–bit edition of Microsoft Windows XP (SP3), Vista, Windows 7 or Windows 8 (not Windows RT).
Beta software: Linux Debian, OpenSUSE and Fedora derived distributions, OS X (Mac).
Ports: USB 2.0 compliant port.
Recommended Processor: 1 GHz.
Memory: 512 MB.
Free disk space: 32–bit: 850 MB, 64–bit: 2 GB.
Operating system: 32– or 64–bit edition of Microsoft Windows XP (SP3), Vista, Windows 7 or Windows 8 (not Windows RT).
Beta software: Linux Debian, OpenSUSE and Fedora derived distributions, OS X (Mac).
Ports: USB 3.0 compliant port.

 

Environmental
Operating environment
Temperature range
Humidity

0 °C to 45 °C (20 °C to 30 °C for quoted accuracy)
5% to 80% RH, non–condensing
Storage environment
Temperature range
Humidity

-20 °C to +60°C
5% to 95% RH, non–condensing

 

Physical Properties
Dimensions (including connectors) 210 x 135 x 40 mm (approx 8.2 x 5.3 x 1.5 in)
Weight < 500 g (approx 1.1 lb)

 

Software
PicoScope 6 PicoScope 6 is your complete test and measurement lab in one application. Features include:
Capture modes: oscilloscope, spectrum and persistence.
Channel maths: calculate the sum, difference, product, inverse or create your own custom function using standard arithmetic, exponential and trigonometric functions.
Mask limiting testing: pass/fail, failure count, total count.
Serial Decoding: decode data from a serial bus such as I²C.
Automated measurements
Scope mode: AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak–to–peak, rise time and rising rate.
Spectrum mode: frequency at peak, amplitude at peak, average amplitude at peak, total power, total harmonic distortion (THD % and THD dB), total harmonic distortion plus noise (THD+N), spurious-free dynamic range (SFDR), signal+noise+distortion to signal+noise ratio (SINAD), signal to noise ratio (SNR) and intermodulation distortion (IMD).
Export data formats: comma separated values (CSV), tab delimited (TXT), Windows bitmap (BMP), graphics interchange format (GIF), portable network graphics (PNG), MATLAB 4 format (MAT).
Operating systems supported: Microsoft Windows XP (SP3) to Windows 8 (stable software), Linux and OS X for Mac (beta software).
Full details for PicoScope 6
Software development kit Includes drivers and example code for various programming languages including C, Excel, LabVIEW and Visual Basic. Download SDK

 

Language Support
Software
PicoScope 6

Full support for: English, Deutsch, Español, Français, Italiano
Menus and dialogs only for: 中文 (简体), 中文 (繁體), Čeština, Dansk, suomi, Ελληνικά, Magyar, 한국어, 日本語, Norsk, Polski, Português, română, Русский, Svenska, Türkçe
Documentation
User’s guide

English, Français, Deutsch, Italiano, Español, 中文

 

General
Data sheet English 中文 (简体), Deutsch, Español, Français, Italiano
Additional hardware (supplied) 2 x MI007 probes, USB 2.0 cable, user manuals, software CD–ROM
PC interface USB 2.0
Power requirements Powered from USB port
Compliance European EMC and LVD standards
FCC Rules Part 15 Class A
RoHS compliant
Total Satisfaction Guarantee In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days.
Warranty 5 years

Note: quoted specifications apply when using PicoScope 6 software.