⬇️ DOWNLOAD THE 3RD EDITION OF THE EMI/EMC CATALOG SIGLENT CATALOG ⬇️

Auswahltabelle für HF-Überwachungsstromzangen (TekBox-Modelle)

Posted by Gianmarco 12.12.2024 0 Comment(s) 3310 Messtechnik,

RF Current Monitoring Probes

The voltage produced by RF current monitoring probes into a 50-ohm load is proportional to the current flowing through the wires going through the probe aperture. RF current monitoring probes, like LISNs, are used to measure conducted emissions. RF current probes measure the current of conducted emissions, whereas LISNs measure the voltage. Current monitoring probes are not intrusive. It is not necessary to separate the wire harness under test. In addition, RF current monitoring probes typically cover a wider frequency range than LISNs. The EMC standards indicate where LISNs must be used and where current monitoring probes must be used. The primary use is conducted emission measurement on data or control cables. Furthermore, RF current monitoring probes are very versatile tools for the investigation and improvement of EMC issues and for many other applications.
Tekbox RF current monitoring probes cover the frequency range up to 1 GHz. The series with fixed aperture are especially inexpensive. In circumstances, where the cable harness cannot simply be disconnected to feed it through the aperture, Tekbox offers the TBCP2 series snap on probes.
To calculate the corresponding current flowing through the wires passing the probe aperture, subtract the individually documented trans-impedance value in [dB] from the probe's output voltage.

  TBCP1-200 TBCP1-250 TBCP1-500 TBCP2-250 TBCP2-30K400 TBCP2-500 TBCP2-750 TBCP3-1000 TBCP4-250 TBCP4-500 TBCP4-750
Model TBCP1-200 TBCP1-250 TBCP1-500 TBCP2-250 TBCP2-30K400 TBCP2-500 TBCP2-750 TBCP3-1000 TBCP4-250 TBCP4-500 TBCP4-750
Characterized
frequency range
1kHz - 500MHz 1kHz - 300MHz 1kHz - 500MHz 1kHz - 400MHz 10Hz - 500MHz 1kHz - 600MHz 1kHz - 1GHz 1kHz - 1GHz 1kHz - 400MHz 1kHz - 600MHz 1kHz - 1GHz
3dB bandwidth 40kHz - 200MHz 300kHz - 250MHz 400kHz - 500MHz 300kHz - 300MHz 30kHz - 400MHz 1MHz - 500MHz 1.5MHz - 850MHz 3MHz - 1GHz 200kHz - 300MHz 400kHz - 500MHz 1.5MHz - 850MHz
Trans-impedance 17 dBΩ 18 dBΩ 19 dBΩ 13 dBΩ 3 dBΩ 16 dBΩ 20 dBΩ 20 dBΩ 13 dBΩ 16 dBΩ 20 dBΩ
Aperture
diameter
25 mm 25 mm 25 mm 32 mm 32 mm 32 mm 32 mm 17 mm 32 mm 32 mm 32 mm
Snap on / hinge no no no yes yes yes yes no no no no

RF Surface Monitoring Probes

RF Surface current monitoring probes are utilised in applications where RF currents flowing on surfaces such as PC groundplanes or traces, metal planes or wires must be measured.

  TBSCP1-5M300 TBSCP1-10M500
Model TBSCP1-5M300 TBSCP1-10M500
Characterized frequency range 30 kHz - 400 MHz 30 kHz - 600 MHz
Trans-impedance -7 dBΩ -5 dBΩ
Footprint 40 x 15 mm 40 x 15 mm

Coaxial RF Current Monitoring Probes

Coaxial RF current monitoring probes are used to measure RF currents in coaxial cables. They can be used as general purpose coupling devices to measure RF power or as loop antenna transducers.

  TBCCP1-2K70 TBCCP1-3K100 TBCCP1-400K600
Model TBCCP1-2K70 TBCCP1-3K100 TBCCP1-400K600
Characterized frequency range 10 kHz - 100 MHz 10 Hz - 100 MHz 10 Hz - 600 MHz
Trans-impedance 0 dBΩ +5 dBΩ +23 dBΩ
Application Transducer for large loop antennas (LLA) General purpose coupling device General purpose coupling device

RF pulse Current Monitoring Probes

RF pulse Current Monitoring Probes are typically used for surge or RF pulse current monitoring applications in the time domain.

  TBPCP1-20100 TBPCP2-3070
Model TBPCP1-20100 TBPCP2-3070
Characterized frequency range 1 Hz - 200 MHz 1 Hz - 200 MHz
3 dB frequency range 20 Hz - 100 MHz 30 Hz - 70 MHz
Transfer Impedance (high Z) 0.2 V/A 0.1 V/A
Transfer Impedance (50 Ohm) 0.1 V/A 0.05 V/A
Droop rate < 10% / ms < 20% / ms
Rise time < 5 ns < 5 ns
Aperture diameter 25 mm 5.5 mm

Current Probe calibration fixtures

Current Probe Calibration Fixtures are used for calibrating and measuring the trans-impedance of current probes. Calibrators are also required for the calibration of immunity test setups with BCI probes.


Bulk Current Injection Probes

Bulk Current Injection Probes are used to inject RF-current into cables of electrical equipment to test the susceptibility against radiated electromagnetic energy. Tekbox BCI-probes can be clamped around wire bundles with up to 27 mm. They are designed to meet the specifcations of the standards IC 61000-4-6 (domestic and industrial products) and ISO 11452-4 (automotive products).

Tekbox supplies suitable wideband power amplifiers to drive the BCI probes:

  • TBMDA-CDN25 for immunity tests according to IC 61000-4-6
  • TBMDA-BCI25 for immunity tests according to ISO 11452-4

The calibration fixture TBBCI1-CAL is suitable for both BCI-probe models.

  TBBCI1-200K280 TBBCI1-800K420 TBBCI1-CAL
Model TBBCI1-200K280 TBBCI1-800K420 TBBCI1-CAL
Frequency range 10 kHz - 300 MHz 10 kHz - 500 MHz 150 kHz - 400 MHz
Coupling loss 8 dB typical 5 dB typical -
Maximum RF input power 50 W 50 W 500 W
Aperture diameter 27 mm 27 mm -
Outer dimensions 92 x 76 mm 92 x 76 mm 200 x 150 x 140 mm
Application / Standard BCI probe for IEC / ISO 61000-6-4 BCI probe for IEC / ISO 11452-4 BCI probe calibrator for IC / ISO 61000-6-4, IEC / ISO 11452-4