Votre panier est vide!
Fluke 1672, 1673 FC and 1674 FC multifunction installation testers. Simplified setup, faster testing, easier reporting. A state-of-the-art solution that enables testing up to 30 percent faster and reduces documentation time by up to 50 percent
Fluke 1672, 1673 FC and 1674 FC Multifunction Installation Testers
Simplified setup, faster testing, easier reporting
A state-of-the-art solution that enables testing up to 30 percent faster and reduces documentation time by up to 50 percent
Fluke 1670 Series multifunction installation testers will revolutionize the way you work. With an ergonomic design, intuitive user interface, built-in data management capabilities, wireless connectivity (1673 FC and 1674 FC) and comprehensive reporting software, the 1670 series sets the new standard for an integrated installation test solution.
Reliable installation testing is essential to ensure the safety, perfect functionality and integrity of a facility's electrical systems. The robust design of the 1670 series allows you to test the safety of electrical systems in domestic, commercial and industrial applications while meeting the requirements of IEC/HD 60364-6 and all local regulations for installation testing.
With the 1670 series, you will be able to perform the necessary tests faster, as well as reduce the time spent on documentation, all with maximum reliability of the data collected.
| New features of the 1670 series | 1662 | 1663 FC | 1664 FC | 1672 | 1673 FC | 1674 FC |
| Color touch screen | - | - | - | ✔ | ✔ | ✔ |
| Lithium-ion battery | - | - | - | ✔ | ✔ | ✔ |
| USB-C port supports charging and data transfer | - | - | - | ✔ | ✔ | ✔ |
| Digital selector - supports additional new features | - | - | - | ✔ | ✔ | ✔ |
| Acquisition of the form | - | - | - | ✔ | ✔ | ✔ |
| Project configuration | - | - | - | ✔ | ✔ | ✔ |
| Field upgradeable | - | - | - | ✔ | ✔ | ✔ |
| Bidirectional data | - | - | - | ✔ | ✔ | ✔ |
| Maximum voltage 660V, operation at 600V | - | - | - | ✔ | ✔ | ✔ |
| Pass/fail limits | - | - | - | ✔ | ✔ | ✔ |
| Measurement of voltage drop | - | - | - | ✔ | ✔ | ✔ |
| Device isolation monitoring test (IMD) | - | - | - | - | - | ✔ |
| Test of overvoltage protection device (SPD) | - | - | - | - | - | ✔ |
| Saving results from additional Fluke Connect tools | - | - | - | - | ✔ | ✔ |
| User Programmable Auto Test Sequence | - | - | - | - | - | ✔ |
| Features shared between the 1660 series and the 1670 series | ||||||
| Verification of wiring polarity, detection of broken PE and N wires | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| Insulation resistance | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| Continuity and resilience | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| Measurement of motor windings with continuity test (at 10mA) | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| Loop and line impedance | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| Assumed Ground Fault Current (PEFC/IK) | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| Presumed short-circuit current (PSC/IK) | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| RCD tripping time/ RCD tripping current (ramp test) | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| Measures tripping time and current for RCD type AC, A and F in one test | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| RCD variable test current | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| Automatic RCD self-test sequence | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| Phase sequence test | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| AC voltage, DC voltage and frequency | AC only | ✔ | ✔ | ✔ | ✔ | ✔ |
| Isolation on inputs L-N, L-PE, N-PE | 250V, 500V, 1000V | 250V, 500V, 1000V | 50V, 100V, 250V, 500V, 1000V | 250V, 500V, 1000V | 250V, 500V, 1000V | 50V, 100V, 250V, 500V, 1000V |
| Continuity on inputs L-N, L-PE, N-PE | - | ✔ | ✔ | ✔ | ✔ | ✔ |
| EV Test 6 mA DC (RCD A/EV, RCD B/Mi, RDC-DD) | - | ✔ | ✔ | - | ✔ | ✔ |
| Ground resistance | - | ✔ | ✔ | - | ✔ | ✔ |
| Standard self-test sequence | - | - | ✔ | - | ✔ | ✔ |
| Safety function Insulation PreTest | - | - | ✔ | - | - | ✔ |
| Loop and line impedance, mΩ resolution | - | - | ✔ | - | - | ✔ |
| Automatic pass/fail results | - | - | - | ✔ | ✔ | ✔ |
| Compatibility with the Fluke Connect app | - | ✔ | ✔ | - | ✔ | ✔ |
| Fluke Cloud Storage | - | ✔ | ✔ | - | ✔ | ✔ |
| Automatic start selectable on/off for circuit and RCD testing | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| USB-C/BLE | IR-USB | IR-USB/BLE | IR-USB/BLE | USB-C | USB-C/BLE | USB-C/BLE |
| Memory | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
| Z Max Memory | - | ✔ | ✔ | - | ✔ | ✔ |
Leave a Comment