⬇️ DOWNLOAD THE 3RD EDITION OF THE EMI/EMC CATALOG SIGLENT CATALOG ⬇️

GW Instek LCR-6100, 10Hz - 100kHz High Precision LCR Meter

GW Instek LCR-6100, 10Hz - 100kHz High Precision LCR Meter

GW Instek LCR-6100, 10Hz - 100kHz High Precision LCR Meter

Main Features LCR-6000 series:
- 3.5” color LCD
- 5 models (10Hz~2kHz/20kHz/100kHz/200kHz/300kHz)
- Consecutive test frequency
- Basic accuracy : 0.05%
- Measuring speed up to 25ms (max.)
- Full frequency range or spot OPEN/SHORT
- 16 major/secondary parameter measurement combinations and two additional monitoring parameters (maximum four different parameters can be shown simultaneously)
- DCR measurement and internal D.C. bias voltage (±2.5V)
- PASS/FAIL judgment
- Auto Level Control (ALC) function
- BIN function provides 9BIN and 1AUX, totally 10 BIN
- 10 steps listed tests to select different frequency, voltage and current criteria
- Standard interface : RS-232C, Handler and USB storage
- Compact size, ideal for automatic equipment (2U,1/2 RACK)

Description
GW Instek introduces the brand new high precision LCR meter─LCR-6000 series, which, with five models, has a test frequency range extending from 2kHz/20kHz/100kHz/200kHz/300kHz (maximum) and with 0.05% basic accuracy. The compact size design, 2U height and 1/2 rack, is one of the practical features of the series which is the optimum space saver suitable for either bench top or system rack. The compacted LCR-6000 series with abundant features is absolutely the excellent tool for R&D, production test, IQC, etc. on implementing each test stages for passive components.
The LCR-6000 series provides rich functionalities with the compact size. First of all, the entire series adopts 3.5-inch color LCD and features opulent display parameters. In addition to simultaneously displaying setting criteria and measurement results, the series increases two additional monitoring parameters. In other words, there are four parameters, primary/secondary and two monitoring, simultaneously shown on the screen that tremendously enhances the measurement efficiency. The enlarge display mode not only emphasizes the measurement results, but also provides PASS/FAIL judgment to facilitate a rapid and convenient test result.
Convenience is one of the unique features. The LCR-6000 series comes equipped with two zero methods, which are full frequency range and spot. Users, without turning off the power and changing test fixture, can freely change frequency within the provided frequency range to conduct measurements. By so doing, tremendous time can be saved from repeatedly executing zero operation. Additionally, frequency range of the series is consecutive that allows users to input precise frequency value to conduct the most genuine test on components.
The LCR-6000 series also features diverse ancillary measurements to meet the measurement requirements of different materials. For instance, the series provides the automatic level control (ALC) function to satisfy the test voltage requirement of MLCC. For inductive component measurements, the series provides the adjustable test current function and the D.C. resistance measurement function. The optional external bias current adapter (±2.5A) is to satisfy the measurement requirements. With respect to the D.C. bias voltage test for capacitive components requirements, the series allows users to conduct verification measurement on materials by its internal ±2.5V adjustable voltage or via an optional external bias voltage adapter (±45V). Furthermore, 10 steps of listed test functionalities allow users to set testing parameters (either by frequency, or voltage, or current) for each step based on users’ requirements in order to observe the trend of DUT characteristics.
The LCR-6000 series has 10 memory sets defined by panel setting criteria to facilitate users in selecting test criteria and saving time in repeated settings. 10,000 measurement result storage capability can easily record measurement results instantaneously. The USB host allows easy access to recorded results without connecting the series to the PC. The USB host also allows USB to retrieve and save screen so as to assist users in compiling setting guidelines.
For the external control, the LCR-6000 series provides handler interface and collocates with its measurement sorting function (9BIN, AUX: 1BIN) to facilitate the connection with sorting machine so as to sort out the materials. For remote control and measurement result retrieval requirements, the LCR-6000 series provides RS-232C to assist setting control or measurement result retrieval via the PC commands. Additionally, the free PC software gives users an instant tool to store measurement results that saves time in developing programs.
The brand new compacted LCR-6000 series can effectively improve the limitation of space. Diverse measurement functionalities and display methods are making the series the high CP ratio choice in meeting the requirements of R&D, component assessment for engineering departments, category sorting requirements for component production, and IQC for verification on component specifications.
 
Consecutive frequency and Convenient zero function
The LCR-6000 series, within the provided frequency range, features consecutive and adjustable frequency capability which allows users to conduct measurement and analysis on components with the most genuine frequency requirements. For OPEN/SHORT fixture compensation function, the LCR-6000 series is equipped with full frequency range zero and spot zero selections. After executing full frequency range zero, users, under the conditions of not turning off the power and not changing test fixture, can freely change test frequency for the LCR-6000 series to execute component measurements that tremendously saves time in repeatedly zeroing test fixture after changing frequency.
 
Rich and diverse information display
The measurement result display of the LCR-6000 series not only reveals primary and secondary measurement parameters but also includes two monitoring parameters. Therefore, four DUT related parameters can be simultaneously shown on the display screen to save time if repeated measurements are required. With respect to display screen, the LCR-6000 series features diverse display to meet users’ observation requirements. For instance, MEAS display shows setting parameters and measurement results at the same time; ENLARGE display focuses on measurement results and PASS/FAIL judgment is available, which is conducive to assist engineers to swiftly obtain the validity of measurement results.
 
10 points listed tests and PC software
The LCR-6000 series provides the 10 points listed test function, which allows users to define a set of DUT measurement parameters (such as Cs- Rs) and to set 10 test criteria of category (either by frequency or by voltage or by current) but different values to conduct measurements. Through this function, users can rapidly and clearly obtain DUT’s characteristic variation trend to determine the adaptability of DUT’s practical applications. The measurement results can be recorded directly in the internal memory and be transferred to the PC through USB. The LCR-6000 series also provides free PC software (maximum 1,000 points listed tests) in order to satisfy users’ analytical requirements on delicate variation.
 
Diverse ancillary measurement functions
To satisfy the diverse measurement application requirements for different components and materials, the LCR-6000 series collocates with many auxiliary measurement functions. For capacitor measurement, Automatic Level Control (ALC) is mainly for component which requires a constant or rated test voltage such as multi-layer ceramic capacitor (MLCC). An internal D.C. bias voltage (±2.5V, internal) is allowing simulating A.C. and D.C. coexistence to learn capacitance variation. For inductor measurement, the D.C. resistance measurement function is to validate D.C. resistance characteristics. Additional, the LCZ function is to quickly identify components ’characteristics. When the function is activated, the LCR-6000 series will automatically determine DUTs’ characteristics and reveal the optimum parameters to show the measurement results.
 
Standard interface
For interface connectivity, the LCR-6000 series comes equipped with handler interface and RS-232C interface. Handler outputs 10 BIN (9BIN, AUX: 1BIN) sorting results that is best for external connection control, for instance, connecting to a sorting machine to conduct components’ sorting operation. RS-232C is suitable for remote control and measurement results retrieval. The PC gives commands to control settings or to read measurement results so as to achieve the requirements of verifying automotive applications.

Écrire une critique

Remarque: HTML n`est pas traduit!
    Mal           Bien

Batter Fly s.r.l. is an Italian company established in 2002 with VAT number IT02235301203

Main contacts: telephone +39 051 6468377 email [email protected]

The address of our headquarters is Via Collodi 7a, 40012 Calderara di Reno (BO) Italy

All shipments depart from the address of our office indicated above by express courier unless otherwise specified in the order confirmation

For customers resident in Italy, both private and corporate, we apply the VAT of 22%

If the customer has specific VAT exemptions, he must communicate this before issuing the purchase order

For private customers residing outside Italy but within the European Union we apply the VAT of the country of destination

For corporate customers residing outside of Italy but within the European Union we do not apply VAT. However, VAT may be applied in the event that the customer enters an incorrect or non-certified VAT number by the VIES system

Customers can send purchase orders either through the website or by requesting a personalized quote using the specific form or through our main contacts indicated above

Batter Fly has been present for years within the MePa, the electronic market of the public administration. If one or more products are not present, contact us and we will load what is necessary quickly

Product availability is indicated on the product page of interest in various ways:
- Units in stock: 1 or more | indicates the actual units available
- Units in stock: 0, std delivery. 2 weeks | indicates the standard weeks that the supplier indicates for procurement
- Units available arriving on 10/24/2022: 3 | indicates that there will be available units arriving on that data

Products ordered before 3pm are shipped the same day, orders received after 3pm will be shipped the next working day

Each shipment is associated with a tracking number that will be communicated via email to the customer after taking charge by the shipper

To see the shipping costs go here https://www.batterfly.com/shop/consegna

To see the payment methods go here https://www.batterfly.com/shop/pagamenti

For any other questions please contact us through our main contacts

  • Vues: 17796
  • Marque: GW Instek
  • Code produit: LCR-6100
  • MPN: 01CR610000GT
  • EAN: 4719692508775
  • Garantie: 2 ans
  • Unités en stock ➡ 0, délai 3 semaines
  • Prix net:
  • 1.786,00€
  • Prix TVA incluse: 2.178,92€

Mots clés: gwinsteklcr6000

Desco Europe SCS 700810 MOISTURE BARRIER BAG, DRI- SHIELD 2000, 200x255MM, 100 EA 0.0036" (3.6 mil)..
91,76€
TekBox TBFL1 is a combined transient limiter / attenuator / high pass filter, designed to provide op..
333,00€
Ansell Sensilite® 48100-8 Fingers white size 8 -25%
Ansell Sensilite® gloves are used for general use. Seamless continuous thread fabric and knitted wri..
1,60€ 1,20€
Desco Europe VERMASON 242273 TAPE, WESCORP,CLEAR,ESD SYMBOL 48MM x 65.8M, 76.2MM CORE Ideal in pack..
37,65€
Rohde & Schwarz FPH-K43 Receiver Mode and Channel Scanner Measurement Application for FPH Spectrum R..
1.180,00€