⬇️ DOWNLOAD THE 3RD EDITION OF THE EMI/EMC CATALOG SIGLENT CATALOG ⬇️

RIGOL DNA5000 & DNA6000 Introduction: Vector Network Analyzers (VNA)

Posted by Batter Fly 02/03/2026 0 Comment(s) 709 Test y Medida,

Discover the new Rigol DNA5000 and DNA6000 series modular vector network analyzers. Performance up to 26.5 GHz in a compact 2 or 4-port format for ultra-high precision RF measurements.

RIGOL introduces the DNA5000 and DNA6000 series, the new generation of vector network analyzers (VNA) designed to offer flexibility, portability, and high performance in a compact format. With a frequency range starting from 5 kHz up to 26.5 GHz, these solutions offer superior stability with a dynamic range >120 dB and integrated tools such as TDR analysis and Smith charts, along with advanced USB/LAN/HDMI connectivity. This design allows for control via external displays, PCs, or integration into automated test systems (ATE), optimizing space in research and production laboratories.

Both series offer an exceptional dynamic range (up to 127 dB typical) and support a wide variety of mechanical and electronic calibrations (ECal), ensuring precise, stable, and repeatable RF and microwave measurements for characterizing passive and active components.

DNA5000 Series: 2-Port Precision

DNA5000 series represents the ideal solution for 2-port VNA tests. Lightweight (only 5.3 kg) and compact, it covers maximum frequency ranges of 4.5 GHz, 8.5 GHz, 14 GHz, 20 GHz, and 26.5 GHz depending on the model. It offers an excellent trace noise of 0.005 dB and a frequency resolution of 1 Hz, making it perfect for education, R&D, and the production of standard radio frequency devices.

DNA6000 Series: Up to 4 Ports and Extreme Performance

DNA6000 series is designed for the most demanding and complex applications. In addition to covering the same frequency ranges (up to 26.5 GHz), it introduces the option to choose 4-port models, which are essential for the complete characterization of multi-port networks, mixers, balanced filters, and differential amplifiers. The hardware is further optimized, ensuring trace noise lowered to just 0.003 dB for maximum measurement stability.

Specifications Comparison and Main Differences

Both DNA5000 and DNA6000 series offer an extraordinary dynamic range (127 dB typical) and an output power up to 10 dBm. Both integrate Time Domain Analysis (TDA), support for advanced calibrations, and convenient control via Web Control and SCPI. The choice between the two series primarily depends on the need to perform simultaneous multi-port measurements (4-port models are only available in the DNA6000 series) and the level of trace noise precision required by the test setup.

Model Number of Ports Frequency Range Trace Noise (Typ.) Connector
DNA5042 2 Ports 5 kHz - 4.5 GHz 0.005 dBrms Type-N (F)
DNA5082 2 Ports 5 kHz - 8.5 GHz 0.005 dBrms Type-N (F)
DNA5142 2 Ports 5 kHz - 14 GHz 0.005 dBrms Type-N (F)
DNA5202 2 Ports 5 kHz - 20 GHz 0.005 dBrms 3.5 mm
DNA5262 2 Ports 5 kHz - 26.5 GHz 0.005 dBrms 3.5 mm
DNA6082 2 Ports 5 kHz - 8.5 GHz 0.003 dBrms Type-N (F)
DNA6142 2 Ports 5 kHz - 14 GHz 0.003 dBrms Type-N (F)
DNA6202 2 Ports 5 kHz - 20 GHz 0.003 dBrms 3.5 mm
DNA6262 2 Ports 5 kHz - 26.5 GHz 0.003 dBrms 3.5 mm
DNA6084 4 Ports 5 kHz - 8.5 GHz 0.003 dBrms Type-N (F)
DNA6144 4 Ports 5 kHz - 14 GHz 0.003 dBrms Type-N (F)
DNA6204 4 Ports 5 kHz - 20 GHz 0.003 dBrms 3.5 mm
DNA6264 4 Ports 5 kHz - 26.5 GHz 0.003 dBrms 3.5 mm
Additional specifications
Frequency Range Dynamic Range (typ.) Trace noise (typ.) Max Output Power
100 kHz to 10 MHz 115 dB 0.003 dB +5 dBm
10 MHz to 6.5 GHz 127 dB 0.0015 dB +8 dBm
8.5 GHz to 14 GHz 122 dB 0.002 dB +8 dBm
14 GHz to 20 GHz 115 dB 0.0025 dB +6 dBm
20 GHz to 26.5 GHz 110 dB 0.005 dB 0 dBm
Broad Frequency Range
Broad Frequency Range for Diverse Applications

Delivering a frequency range from 5 kHz to 26.5 GHz with 2 standard test ports, this analyzer precisely covers testing requirements ranging from basic passive components to material dielectric constant analysis and high-speed interconnects.

Superior Performance & Stability
Superior Performance & Stability

Achieve precise characterization with a wide dynamic range >120 dB and low trace noise, ensuring stability even when testing high-suppression devices.

Advanced Analysis Tools
Advanced Analysis Tools Built-In

Accelerate your workflow with essential integrated tools including Pass/Fail limits, SWR, Smith Charts, and TDR—perfect for both the lab and the production floor.

De-embedding
True Device Performance via De-embedding

See the real performance of your DUT. Our Fixture Removal and De-embedding features strip away errors caused by cables and adapters, delivering the true S-parameters you need.

Intuitive Calibration
Intuitive Calibration

No more guesswork. The step-by-step Calibration Wizard guides users of all skill levels to achieve accurate, calibrated setups in seconds.

Mechanical or Electronic Calibration
Mechanical or Electronic Calibration

Choose the precision of the durable mechanical kits or the speed and consistency of the Electronic Calibration (E-Cal) modules to maximize testing efficiency.

Accessory Support
Complete Accessory Support

Get up and running faster with the comprehensive ecosystem of accessories—your one-stop shop for reliable testing.

Drop-In Compatibility
Drop-In Compatibility

Upgrade your test system effortlessly. With standard SCPI support and command set compatibility, you can integrate this unit into existing automated systems without rewriting code.